linline Concentration Control m-lCC 2.45
|
 |
The cortoller (A) is the central evaluation unit for between
one to four measuring points. Ln the display you can see
measurement values such us concentration, density or other
concentration units with the related process temperature.
All measurement values are digitally available through the
RS 232 interface. The main
measurement value for the concentration is transferred to
the process control system by the classical 0/4 _ 20 mA
current interface. You can adapt the system parameters and
the calibration data to your specific measuring task by
using the well_ structured multilingual menu of the
controller.
The complete microwave electronics are mounted in the
extraordinarily compact microwave module (B) which is
installed close to the sensor (C). |
the
microwave module gets its power supply from the controller by using
a coaxial cable (with a max. length of 150 m) which also guarantees
the digital transmission of the measured data between module and
controller.This concept allows a flexible choice for installation
places for the components (A), (B) and (C).
Modular extension for 4 measurements
|
 |
The controller lCC 2.45 has 4 isolated outputs 0/4 _ 20 mA.
For the realisation of more than one measurement up to 4
microwave modules can be connected. Each module has its own
settings and calibration to measure independently from the
other modules. The calibration and setting of each
measurement can be effected without interference from the
measuring channels which are already used for process
control. Each measurement and its settings can be shown
separately on a big display or you can choose all 4
measuring values in the display together.
Even if you only operate one measurement: the remaining
measuring channels can be used for different ranges or
different calibrations (product specific multiple
calibrations). |
The
power supply of the module and the digital data communication
between each microwave module and the controller is effected by a
coaxial cable with a max. length of 150 m. Hereby you always find
the optimal installation place for the controller.
|